Fully automatic OCV test coating line

  • Product number:

Product Details

  1. Equipment introduction


  The equipment disassembles the battery cells after the OCV test is completed, and after entering the encapsulating machine, they undergo code scanning/weighing/thickness measurement/covering/folding/sticking of insulation meson/appearance inspection/automatic blanking.


  2. Equipment process

image.png

1. Equipment parameters

Serial number

Process requirements

Specific parameters

1

Voltage range

0-5000mV

2

Resistance range

0-3Ω

3

Internal resistance test accuracy

±(0.5%rdg+10dgt)

4

OCV voltage test accuracy

≤±0.1mV

5

Voltage resolution

2uV

6

Internal resistance resolution

1uΩ

7

Time resolution

1mS

8

Test frequency

1KHz±0.2Hz

9

Probe resistance

≤2mΩ

10

Weighing range

010 kg

11

Weighing accuracy

±0.1 g (equipment accuracy 0.05g)

12

Thickness measurement range

50100mm

13

Thickness measurement accuracy

±0.01mm (equipment accuracy 0.01mm)

14

Thickness measurement pressure

0~60kg, accuracy ±1kg

15

The battery core is cleaned with a brush before encapsulating

Clean surface dust and particles

16

Glue spacing

20-80mm

17

Pull film tension

Adjustable tension value

18

Wrap up

No uplift

19

Envelope wrinkles

No wrinkles

20

Repeatability of glue drawing and film cutting

Between ±0.5mm

21

Patch offset

0.5mm

22

Envelope height

The envelope is higher than the upper surface of the battery 2-5mm, adjustable, accuracy ±0.2mm, pass rate ≥99.9%

23

Flanging of pole surface

2-6mm

24

Bubbles in the envelope

Large surface: bubble diameter ≤1mm, single surface ≤3


Side: bubble diameter ≤1mm, single side ≤1


Bottom surface: bubble diameter ≤ 2mm, single side ≤ 5


25

Top patch deviation

≤0.5mm

26

Qualified rate of encapsulation (incoming material control)

99.9%

27

Equipment Capability Index CMK

≥1.67

28

30-day failure rate

≤1%

29

noise

≤75db

 


Core technical capabilities