1. Equipment introduction
The equipment disassembles the battery cells after the OCV test is completed, and after entering the encapsulating machine, they undergo code scanning/weighing/thickness measurement/covering/folding/sticking of insulation meson/appearance inspection/automatic blanking.
2. Equipment process
1. Equipment parameters
Serial number | Process requirements | Specific parameters |
1 | Voltage range | 0-5000mV |
2 | Resistance range | 0-3Ω |
3 | Internal resistance test accuracy | ±(0.5%rdg+10dgt) |
4 | OCV voltage test accuracy | ≤±0.1mV |
5 | Voltage resolution | 2uV |
6 | Internal resistance resolution | 1uΩ |
7 | Time resolution | 1mS |
8 | Test frequency | 1KHz±0.2Hz |
9 | Probe resistance | ≤2mΩ |
10 | Weighing range | 0~10 kg |
11 | Weighing accuracy | ±0.1 g (equipment accuracy 0.05g) |
12 | Thickness measurement range | 50~100mm |
13 | Thickness measurement accuracy | ±0.01mm (equipment accuracy 0.01mm) |
14 | Thickness measurement pressure | 0~60kg, accuracy ±1kg |
15 | The battery core is cleaned with a brush before encapsulating | Clean surface dust and particles |
16 | Glue spacing | 20-80mm |
17 | Pull film tension | Adjustable tension value |
18 | Wrap up | No uplift |
19 | Envelope wrinkles | No wrinkles |
20 | Repeatability of glue drawing and film cutting | Between ±0.5mm |
21 | Patch offset | ≤0.5mm |
22 | Envelope height | The envelope is higher than the upper surface of the battery 2-5mm, adjustable, accuracy ±0.2mm, pass rate ≥99.9% |
23 | Flanging of pole surface | 2-6mm |
24 | Bubbles in the envelope | Large surface: bubble diameter ≤1mm, single surface ≤3 Side: bubble diameter ≤1mm, single side ≤1 Bottom surface: bubble diameter ≤ 2mm, single side ≤ 5 |
25 | Top patch deviation | ≤0.5mm |
26 | Qualified rate of encapsulation (incoming material control) | 99.9% |
27 | Equipment Capability Index CMK | ≥1.67 |
28 | 30-day failure rate | ≤1% |
29 | noise | ≤75db |